There are many kinds of products produced by the puffing equipment, as shown in the picture below, including corn flakes, nutritional powder, leisure (fried, sandwich) snack food production lines, pet feed, fishing bait, tissue protein, modified starch, bread crumbs, reconstituted nutritional rice, etc., There will be some problems in the process of use. In the after-sales service department of Jinan Hengmai Machinery Equipment Co., Ltd., we often hear some calls from customers about abnormal use and unsatisfactory effects of expanded equipment.
The maintenance and maintenance of puffing equipment are summarized as follows:
(1) Lubricating grease should be added to the box bearing of the expanded equipment in time. After 500 hours of operation, all the lubricating grease should be replaced once. (A proper amount of grease should be added to the new machine before the operation, and the oil should be changed after 200 hours of operation.)
⑵The other bearing parts of the expansion equipment should be filled with grease regularly.
⑶ It is strictly forbidden to use hard objects and heavy hammers in the process of disassembly and assembly of the expansive equipment screws, screw sleeves and other vulnerable parts. It is strictly forbidden to place heavy objects or stand people on the expansion cavity. Imported pump valve
⑷The puffed raw materials of the puffing equipment should be cleaned to prevent foreign objects such as metals from entering the machine and damaging the parts.
⑸Puffing equipment checks the quality of the puffing machine at any time and pays attention to replacing the wearing parts.
⑹Puffing equipment keeps the surrounding area clean.
⑺ When the puffing equipment is shut down for a long time or is not used or the puffed materials are replaced, the materials in the puffing cavity should be cleaned to avoid agglomeration, mildew, or cross-contamination between materials.
⑻As the wearing parts near the discharge port wear relatively fast in the puffing equipment, the wearing parts at the end close to the feed port wear less, so when replacing the wearing parts,
The discharge end starts to be replaced one after another, and it is not advisable to replace multiple parts at once.